User Manual Version: _UM_EN_V3.2.8 AOPOSAS250+/AS230+Series Barcode Scanner
6 Parts of the scanner Figure 1 ① LED ② Exit window ③ Trigger ④ Cable interface port ⑤ Release-hole of the cable ⑥ Beeper Figure 2 Remove the
7 Introduction to installation Note: If any of the below operation is incorrect, turn off the power immediately and check the scanner for any improper
8 Installation - USB The scanner attaches directly to a USB host, and is powered by it. No additional power supply is required. 1.
9 Scanning modes The scanner has two scanning modes: hand-held and auto-detection. When the scanner is scanning, ensure the scan line crosses every
10 Programming instruction Refer to the next page, the steps of programming are: 1. Scan the SETUP bar code on the parameter setting part. 2. Enter
11 Operate the scanner by receiving command via UART Note: 1- The information in this chapter is provided for the scanner with RS232 cable or USB c
12 Interface selection This scanner supports interfaces such as keyboard wedge, RS-232 serial wedge, and USB interface. In most of the cases, simpl
13 Keyboard wedge Keyboard type: As a keyboard interface, the scanner supports most of the popular PCs and IBM terminals. Keyboard layo
14 SETUP Option bar code Option Alpha. entry Keyboard layout USA Turkish F Turkish Q French Italian Spanish Slovak Denmark Japanese German 00*
15 RS-232 interface Flow control: None-The communication only uses TxD and RxD signals without any hardware or software handshaking protoc
i Warning: Ensure that the optional DC adapter works at +5V, especially for the RS-232 interface cable. NOTICE: 1. All software, including
16 SETUP Option bar code Option Alpha. entry Flow control None RTS/CTS (Host idle: Low RTS) RTS/CTS (Host idle: High RTS) XON/XOFF ACK/NAK 00
17 USB interface USB device type: HID keyboard– By setting, the scanner is used as a USB HID keyboard emulation device. The keyboard
18 SETUP Option bar code Option Alpha. entry USB device type HID keyboard HID keyboard for Apple Mac USB virtual COM 00* 01 02 Keyboard layout
19 Hand-held scan & some global settings Scanning mode: Good-read off-The trigger button must be pressed once to activate scanning. T
20 i.e. in ASCII from 20H to 7EH. Alphanumeric character only- If this option is selected, the scanner will output the alphanumeric chara
21 SETUP Option bar code Option Alpha. entry Scanning mode Good-read off Momentary Alternate continue Continue Timeout off 00 01* 02 03 04
22 Indication Power on alert: After power-on the scanner will generate an alert signal to indicate a successful self-test. LED indication: After each
23 Auto-detection scan Auto-detect sensor: By setting Enable, the scanner will start operating if any nearby object has been detected. The lase
24 UPC-A Read: Format System Character Data digits (10 digits) Check digitCheck digit verification: The check digit is optional. Check digit trans.: B
25 SETUP Option bar code Option Alpha. entry Read Disable Enable 00 01* Check digit verification Disable Enable 00 01* Check digit trans. Di
ii Contents Technical specifications ...
26 UPC-E Read: Format System Character “0” Data digits (6 digits) Check digits Check digit verification: The check digit is optional and made as the
27 SETUP Option bar code Option Alpha. entry Read Disable Enable 00 01* Check digit verification Disable Enable 00 01* Check digit trans. Dis
28 UPC-E1 Read: Format System Character “1” Data digits (6 digits) Check digits Check digit verification: The check digit is optional and made as the
29 SETUP Option bar code Option Alpha. entry Read Disable Enable 00 01* Check digit verification Disable Enable 00 01* Check digit trans. Di
30 EAN-13 (ISBN/ISSN) Read: Format Data digits (12 digits) Check digit Check digit verification: The check digit is optional and made as the sum of t
31 SETUP Option bar code Option Alpha. entry Read Disable Enable 00 01* Check digit verification Disable Enable 00 01* Check digit transmiss
32 EAN-8 Read: Format Data digits (7 digits) Check digitCheck digit verification: The check digit is optional and made as the sum of the numerical va
33 Code 39 (Code 32, Trioptic Code 39) Read: Format ⋆ Data digits (variable) Check digit (optional) ⋆Check digit verification: The check digit is op
34 SETUP Option bar code Option Alpha. entry Read Disable Enable 00 01* Check digit verification Disable Enable 00* 01 Check digit transmissi
35 Interleaved 2 of 5 Read: Format Data digits (Variable) Check digit (optional) Check digit verification: The check digit is made as the sum module
iii China Finance ...
36 Industrial 2 of 5 Read: Format Data digits (variable) Max./Min. code length: Refer to Max./Min. code length of Code 39. Code ID setting: Refer to C
37 Matrix 2 of 5 Read: Format Data digits (variable) Check digit (optional) Check digit verification: The check digit is made as the sum module 10 of
38 Codabar Read: Format Start Data digits (variable) Check digit (optional) End Check digit verification: The check digit is made as the sum module
39 Code 128 Read: Format Data digits (variable) Check digit (optional)Check digit verification: The check digit is made as the sum module 103 of all
40 ISBT 128 Read: Format “=” or “&” Data digits (variable) Check digit (optional)Check digit verification: The check digit is made as the sum mod
41 Code 93 Read: Format Data digits (variable) 2 check digits (optional)Check digit verification: The check digit is made as the sum module 47 of the
42 Code 11 Read: Format Data digits (variable) Check digit 1 (optional ) Check digit 2 (optional)Check digit verification: The check digit is present
43 MSI/Plessey Read: Format Data digits (variable) Check digit 1 (optional) Check digit 2 (optional) Check digit verification: The MSI/Plessey h
44 UK/Plessey Read: Format Data digits (variable) 2 check digits (optional)Check digit verification: The UK/Plessey has one or two optional check dig
45 UCC/EAN 128 Read: Format Data digits (variable) Check digit (optional) Check digit verification: The check digit is made as the sum module 103 of
1 Technical specifications Table 1-1 Technical specifications Input voltage 5 VDC ± 0.25V Power 500 mW (Operating); 650 mW (Max.) Current 100 mA (Oper
46 China Post Read: Format 11 Data digits Max. /Min. code length: Refer to Max./Min. code length of Code 39. The code length of China Post is 11. C
47 GS1 DataBar (GS1 DataBar Truncated) GS1 DataBar Truncated is structured and encoded the same as the standard GS1 DataBar format, exce
48 GS1 DataBar Limited Read: Format 16 Data digits Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer to Insertion g
49 GS1 DataBar Expanded Read: Format Data characters (variable) Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer t
50 China Finance Note: This type of barcode is not Omni-directionally decodable. The encodable character set includes numeric 0 to 9. Among the sym
51 SETUP Option bar code Option Alpha. entry Read Disable Enable 00 01* Max. code length 00-99 00-99 10* Min. code length 00-99 00-99 10*
52 G1-G6 & FN1 substitution string setting Format of barcode data transmission Prefix Code name Preamble Code ID Code length Code data Code ID
53 FN1 substitution string setting: The FN1 character (0x1D) in an UCC/EAN128 barcode, or a Code 128 barcode, or a GS1 DataBar barcode can be substitu
54 SETUP Option bar code Option Alpha. entry Prefix string setting 0-22 characters None 00-FF16 00* Suffix string setting 0-22 characters <EN
55 G1-G4 string position & Code ID position Format of barcode data transmission Prefix Code name Preamble Code ID Code length Code data Code I
2 Cable connector pin-outs descriptions Cable connector interface pin-outs The pin-outs descriptions in Table 1 apply to the cable connector on the s
56 String transmission Note: The information in this chapter is closely related to the chapter of String setting. Format of barcode data transmission
57 SETUP Option bar code Option Alpha. entry Prefix transmission Disable Enable 00* 01 Suffix transmission Disable Enable 00 01* Code name transm
58 Test Chart UPC-A UPC-E EAN-8 EAN-13 Code 39 Code 32 A908765439 Code 128 Interleaved 2 of 5 Industrial 2 of 5 (Default setting: Read disable
59 Test Chart (Continued) MSI/Plessey (Default setting: Read disable) UK/Plessey ISBN/ISSN China Post GS1 DataBar (GS1 DataBar Truncated) G
60 Troubleshooting Problem Possible causes Possible solutions No power to the scanner. Check the system power. Ensure the power supply is connected.
61 Maintenance Cleaning the exit window is the only maintenance required. A dirty window may affect scanning accuracy. 1. Do not allo
62 Assembling the stand 1. See the figure above, tighten the screws. 2. Bend the neck to the desired position for scanning. 3. Screw mounting: S
63 ASCII Table for keyboard wedge for RS-232 H L 0 1 0 1 0 Null NUL DLE 1 Up F1 SOH DC1 2 Down F2 STX DC2 3 Left F3 ETX DC3 4 Right
64 Barcode representing non-printable character Notes to make the following barcode: 1. According to different barcode printing software, the method
65 Return default parameters & others WARNING: Default value initialization If you wish to return the scanner to all the factory default setti
3 Default setting for each barcode Table 2 Default setting for each barcode Code type Read enable Check digit verification Check digit transmissionMin
66 Configuration alphanumeric entry barcode
4 Decode zone High-density series Long-range series
5 Dimensions
Kommentare zu diesen Handbüchern